A PHP Error was encountered
Severity: 8192
Message: Unparenthesized `a ? b : c ? d : e` is deprecated. Use either `(a ? b : c) ? d : e` or `a ? b : (c ? d : e)`
Filename: helpers/url_helper.php
Line Number: 162
Backtrace:
File: /home/atcbd/public_html/application/core/CIF_Controller.php
Line: 20
Function: __construct
File: /home/atcbd/public_html/application/controllers/Productview.php
Line: 10
Function: __construct
File: /home/atcbd/public_html/index.php
Line: 293
Function: require_once
A PHP Error was encountered
Severity: Warning
Message: Cannot modify header information - headers already sent by (output started at /home/atcbd/public_html/system/core/Exceptions.php:272)
Filename: libraries/Session.php
Line Number: 688
Backtrace:
File: /home/atcbd/public_html/application/core/CIF_Controller.php
Line: 20
Function: __construct
File: /home/atcbd/public_html/application/controllers/Productview.php
Line: 10
Function: __construct
File: /home/atcbd/public_html/index.php
Line: 293
Function: require_once
A PHP Error was encountered
Severity: Warning
Message: Cannot modify header information - headers already sent by (output started at /home/atcbd/public_html/system/core/Exceptions.php:272)
Filename: libraries/Session.php
Line Number: 688
Backtrace:
File: /home/atcbd/public_html/application/helpers/config_helper.php
Line: 16
Function: set_userdata
File: /home/atcbd/public_html/application/core/CIF_Controller.php
Line: 22
Function: session
File: /home/atcbd/public_html/application/controllers/Productview.php
Line: 10
Function: __construct
File: /home/atcbd/public_html/index.php
Line: 293
Function: require_once
LUTRON DIGITAL THERMOMETER TM-936 - ATCL
LUTRON DIGITAL THERMOMETER TM-936
Features
- 2 in 1, Pt 100 ohm thermometer + Thermocouple
type J/K/R/E/T ) thermometer. - Microcomputer circuit with high performance.
- Wide temperature measuring range.
- Build in ℃ & ℉ select button on the front panel.
- 0.1 degree resolution for Pt 100 ohm & type K/J/T/E.
- Data hold function for storing the desired value .
- Memory function to record the maximum & minimum
reading. - Build in a REL button, useful for relative measurement.
- Sensor select button on the front panel, easy to change
different type probe. - 4 wires PT 100 ohm probe input, 0.00385 alpha
coefficient, meet DIN IEC 751, high precision. - Thermocouple probe accept 5 different types : type K,
type J, type R, type T, type E. - RS 232 data output, easy to connect with computer.
- Optional data acquisition software for data record.
- Auto power off saves battery life.
- Built-in low battery indicator.
- Heavy duty & compact housing case with stand.
- Powered by 006P DC 9V battery.